+86-21-5432 2103

PV Module Aging Test Location: 首页 > Product Solutions > PV Module Aging Test > Power supply for TC & HF(UL standard)

Power supply for TC & HF(UL standard)

Product description Specifications Download

Meet the Thermal cycling test(TC) requirements specified in the 4.11 clause of IEC 61215-2016 standard & MST51 clause of & IEC61730-2016 standard & 35 clause in UL1703 standard. Meet the Humidity-freeze test(HF) requirements in the clause 4.12 of the IEC61215-2016 standard & MST52 clause of IEC61730-2016 & 36 clause in UL1703 standard.

l  Each channel is connected with two separate power supply.

l  Two power supply separately offer Imp & 1% Isc and can be switched according to the temperature on the modules as per the IEC61215 standard to track the internal Electrical Continuity of solar module.

l  With smart soft ware which could judge temperature rising or not.

l  The current of each channel could be set on IPC and controlled to constant value.

l  Low current & over voltage alarm could be recorded and highlight signed.

l  Track the Insulation Continuity & Grounding Continuity of every channel.

l  Real-time curves of current, voltage, temperature of each channel could be showed on the display and history curves could be accessed.

l  The software interface could be selected for IEC62125:2016 & IEC61215: 2005, UL1703.

l  Data of current, voltage, temperature of each channel could be monitored and memorized in the hard disc of the IPC as EXCEL format.


l  Components

Sr, No

Description

Brand

Quantity

1

Cabinet

Zealwe

1

2

IPC

Advantech

1

3

Display

DELL

1

4

Power supply-1

Zealwe

13

5

Power supply-2

Zealwe

13

8

Data logger

Advantech

1

9

Thermocouple

OMEGA

13

l  Key technical datasheet

Description

Item

Parameters

Power   supply-1

voltage   range

0-100V

Voltage accuracy

±1%

Current range

0-20A

Current   resolution

0.1A

Current   accuracy

±1%

Power   supply-2

voltage range

0-100V

Voltage accuracy

±1%

Current range

0-200mA

Current   resolution

1mA

Current   accuracy

±1%

Thermocouple

Temperature   range

-50150

Temperature accuracy

±2

Temperature repeatability

±0.5



  • File name Release date Ooperating
  • No Data